Electric Motor Rewinding Service

motor rewinding

Oceanlink has extensive experience in rewinding AC and DC motors for Marine Industry.

Motor to be rewinded is off landed on arrival and
re-winded motor is delivered back to the vessel before departure.

  • Electric Motor Rewinding
  • Motor Overhaul
  • Thermographic Inspection
  • Alignment
  • Balancing
  • Bearing replacement
motor rewinding

Service ports: Brisbane, Gladstone, Newcastle, Sydney, Melbourne, Perth and Fremantle.

Contact us for electric motor rewinding services in Australia

Complete electric motor rewinding services for the marine and shipping industry.

The rewinding team is available 24/7. For service engagement, please contact +61731362500 (24 hrs hotline) or e-mail [email protected]

AC and DC Motor

Oceanlink has extensive experience in rewinding AC and DC motors for Marine Industry.

Motor to be serviced is off landed on arrival to the port and re-winded at our workshop and later connected back to the vessel before departure.

We ensure a fast turnaround to match the vessel schedule and dynamic marine industry.

Services

  • Electric Motor Rewinding
  • Motor Overhaul
  • Thermographic Inspection
  • Alignment
  • Balancing
  • Bearing replacement

Moisture Content Test of Dry Chemical Powder (DCP)

moisture content test

as per imo 1432, a sample of DCP has to be tested for moisture content bi-anually.

At Oceanlink, we offer labratory services to measure the moisture content in accordance with imo 1432.

Moisture content test

Report with in 3-4 business days

IMO 1432 compliant Lab test

moisture content test

Service ports: Brisbane, Gladstone, Newcastle, Sydney, Melbourne, Perth and Fremantle.

Contact us for moisture content test of DCP in Australia

Oceanlink provides laboratory services for assessing the condition and moisture content test of dry chemical powder in accordance with IMO 1432 31/5/2012.

As per IMO 1432 31/5/2012 under Two-year testing and inspections –

8.2.4 test a sample of dry chemical powder for moisture content.

We are available 24/7 to respond to your DCP moisture content analysis needs. Australia wide service.

For lab services, please contact +61731362500 (24 hrs hotline) or e-mail.

Annual Inspection Fixed Dry Chemical Powder (DCP) System

Dry Chemical Powder System

Oceanlink provides annual inspection of Fire fighting fixed dry chemical powder system in accordance with MSC.1/Circ.1432 – REVISED GUIDELINES FOR THE MAINTENANCE AND INSPECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES.

Dry Chemical Powder System

Dry chemical powder system inspection requirements

As per MSC.1/Circ.1312 –  Ref. T4/4.01 

Annual testing and inspections

7.9 Fixed dry chemical powder systems

  • Visually inspect all accessible components for the proper condition.
  • Verify the pressure regulators are in proper order and within the calibration.
  • Agitate the dry chemical powder charge with nitrogen in accordance with system manufacturer’s instructions.

Two-year testing and inspections

8.2 Fixed dry chemical powder systems

  • Blow-dry nitrogen through the discharge piping to confirm that the pipework and nozzles are clear of any obstructions.
  • Operationally test local and remote controls and section valves.
  • Verify the contents of propellant gas cylinders (including remote operating stations).
  • Test a sample of dry chemical powder for moisture content.
  • Subject the powder containment vessel, safety valve, and discharge hoses to a full working pressure test.

Moisture test of Dry chemical powder (DCP)

Oceanlink provides Fire fighting foam laboratory services for assessing the condition of dry chemical powder in accordance with IMO 1432 31/5/2012.

We are available 24/7 to respond to your foam sample analysis needs.

For lab services, please contact +61731362500 (24 hrs hotline) or e-mail.